INSTRUCTIONS TO CHANGE EXISTING NETSCAPE® V3.x INSTALLATION

Note: You may find it useful to print this page and work from the printed copy - click here

For Windows 3.x, you will have a dialing program to initiate the modem to dial. It will normally be "Trumpet Winsock" or "Shiva". For Windows 3.x follow the instructions under 1(a) below. For Windows 95 follow the instructions under 1(b) below.

1(a). If using Trumpet Winsock, follow this procedure.
(i) Start Trumpet and immediately stop the modem from dialing by pressing <ESC> several times.
(ii) Select File, Setup and in the Name Server box fill in 203.63.149.1
Netmask and Default Gateway should both be set to 0.0.0.0
In the Domain Suffix box fill in techinfo.com.au
Click on Internal PPP. Baud rate should be as high as your PC and modem will allow use either 38400 for a 486 and 57600 for a Pentium.
Both Hardware handshake and Van Jacobson... should have an X in the box.
Online Status Detection should be DCD. Click OK to save this part.

The rest of the settings in this box should be as follows:-
Packet Vector : 00
MTU : 256
TCP RWIN : 864
TCP MSS : 216
Demand Load Timeout : 5 secs
TCP RTO MAX : 60

Time server box should be blank.
(iii) Select File, PPP options. Click in the Use PAP authentication and type in your allocated username and password (in lowercase) from the sheets which have been returned to you.
Click on OK to exit.
(iv) Select Dialer, then select setup.cmd. Enter the dial-up phone number as ,94327222 (Note: the leading comma (,) causes the modem to wait 2 seconds after picking up the line to ensure a dial tone is present). If you have a 56k modem use the ,9433-4444 number instead.
Click OK and enter your allocated username (from the sheets returned to you).
Click OK and enter your allocated password.

1(b). Click on "My Computer" in the top left corner of the Windows "desktop screen".
Double click on "Dial-up networking", then double click on "make new connection"
Using the setup wizard which comes up, fill in the detail as follows:-
The name of the new connection should be: Tech Info The (modem) number to dial is (as above) 9432-7222 Note that the 03 for the area code should already be filled in, if not fill it in now. Make sure the country code is set to Australia (61). These are the only two "vital" pieces of information required. Keep clicking NEXT then Finish to complete the setup of the dialup connection.
Single click with the right mouse button on the Tech Info icon and select Properties from the menu which appears.
Select Server Types from the screen. On the Server Types screen which appears it should have Type of Dial-Up Server as PPP:Windows 95, WindowsNT, Internet in the box. On the rest of the screen only the boxes marked Enable software compression and TCP/IP (under protocols) are the only ones with ticks (or crosses) in them - all others are blank.
Select TCP / IP settings On the page which appears, there should be a "radio button" should be in "Server assigned IP address" and another in "Specify name server address". In the Primary DNS type in (in place of the 0.0.0.0) 203.63.149.1 and in the Secondary DNS type in 203.63.149.2. Both the Primary WINS and Secondary WINS should have 0.0.0.0 in them. Both the Use IP header compression and Use default gateway on remote network should have ticks in the box beside these options.
Press OK then OK to close off the Dial-Up Networking setup then click on the X at the top right hand corners of the boxes open on the screen to close them all and return to a Windows desktop "clean screen".

2. Start Netscape.
Select Options, select General Preferences from the pull-down menu, select the Appearance Tab
In the "startup" section replace the home page location with http://www.techinfo.com.au then press OK

3. Select Options, select Mail and News Preferences from the pull-down menu and select the Servers tab
Change the Outgoing mail (STMP) server to mail.techinfo.com.au (note lowercase text in all that follows)
Change the Incoming mail (POP3) server to mail.techinfo.com.au
Change the POP3 username to xxxx@mail.techinfo.com.au (replace xxxx with your login name)
Change the News (NNTP) server to news.techinfo.com.au
Choose OK
Choose the Identity tab.
Type in your real name i.e Fred Smith (You may use Capitals and abbreviations if you like here in this box)
Type in your e-mail address i.e xxxx@techinfo.com.au (replace xxxx with your login name)
(Note: If you are a previous Gravity Internet customer, use    xxxx@gravity.net.au   in the instructions above)
Type in your Reply To Address, usually the same as your e-mail address i.e. xxxx@techinfo.com.au (again replace xxxx with your login name).
(Note: If you are a previous Gravity Internet customer, use   xxxx@gravity.net.au   in the instructions above)
Type in your Organization, if relevant, i.e. company name then choose OK

4. Select Options,
Select Network Preferences, select Proxies tab, select Manual Proxies, select View,
Set the first three proxies all to the same address i.e. FTP, GOPHER & HTTP to proxy.techinfo.com.au and set the port to 8080 then select OK
This completes the changeover to TECH INFO Internet service.


----------<< MENU >>----------
Check Online Usage // About Us // Check email though web interface // Dial up Access Rates // Dial up Access Application form // Domain hosting rates
Domain hosting application form // Frequently Asked Questions // Sites of interest // Software Setup for Techinfo Internet // Equipment used by our system
Terms and Conditions of use // 56k modem firmware & driver upgrades // Techinfo ftp site // System news // Sites hosted for Business customers

--------------------------------------